P/N
Frequency Range
Maximum Bandwidth
Insertion Loss
Isolation
VSWR
Power
Size
≤(dB)
≥(dB)
≤
(W)
WxLxHmm
DRCE1313T
800-7000MHz
10%
0.5
18
1.3
100
12.7*12.7(Installation hole distance9.7)
DRCE1313TB
12.7*12.7(Installation hole distance10.2)
DRCE1313M
800-7000MHz
10%
0.5
18
1.3
100
12.7*12.7*7.2
DRCE1919X
850-6000MHz
10%
0.4
20
1.25
100
19.0*19.0*8.6
DRCE1919Y
850-4000MHz
10%
0.4
20
1.25
150-500
19.0*19.0*8.0
DRCE6466K
950-2000MHz
Full
0.7
17
1.4
150
64.0*66.0*26.0
Note:
1. The circulator only mentions the passing power, which means the passing power from the transmitter to the antenna and from the antenna to the receiver;
2. The above table only shows some common frequencies, which can be produced according to the frequency required by the user;
3. For drop-in circulators, please use stainless steel or brass screws when installing;
4. If you don’t find what you need, please contact us;
Contact: Vic Wang
Phone: 86-18520839701
Tel: 86-18520839701
Email: sales@esjtechnology.com
Add: 8th Floor, Huafeng Building, No. 6006, Shennan Road, Zijing Community, Lianhua Street, Futian District, Shenzhen, China